If your organisation has ever reported a carbon footprint, answered a CDP questionnaire or prepared a CSRD climate disclosure, it almost certainly used the Greenhouse Gas Protocol. Developed by the World Resources Institute (WRI) and the World Business Council for Sustainable Development (WBCSD), the GHG Protocol is the accounting rulebook that defines what counts as “your” emissions and how to sort them into Scopes 1, 2 and 3.
This guide explains the core GHG Protocol Corporate Standard, the Scope 2 Guidance and the Scope 3 Standard for beginners. It also covers the biggest change in the Protocol’s history: a joint revision with ISO that, as of November 2026, is scheduled for consultation in Q2 2027 and publication in Q4 2028.
What the GHG Protocol is
The GHG Protocol is a family of voluntary standards. The three that matter most for company reporting are:
| Standard | Current edition | What it covers |
|---|---|---|
| Corporate Accounting and Reporting Standard | Revised edition (2004); first edition September 2001 | Boundaries, Scopes 1 and 2, base years, reporting |
| Scope 2 Guidance | 2015, an amendment to the Corporate Standard | How to account for purchased electricity, heat, steam and cooling |
| Corporate Value Chain (Scope 3) Standard | September 2011 | The 15 categories of value chain emissions |
The Corporate Standard requires companies to account for and report Scopes 1 and 2 at a minimum. Scope 3 is optional under the Corporate Standard itself, but if you follow the Scope 3 Standard you must account for all Scope 3 emissions and disclose and justify any exclusions. In practice, regulation has now made Scope 3 hard to avoid for large companies (see below).
The seven greenhouse gases
An inventory must cover the seven gases listed by the GHG Protocol: carbon dioxide (CO2), methane (CH4), nitrous oxide (N2O), hydrofluorocarbons (HFCs), perfluorocarbons (PFCs), sulphur hexafluoride (SF6) and nitrogen trifluoride (NF3). NF3 was added through a February 2013 amendment on required gases and global warming potential (GWP) values. Each gas is converted to tonnes of CO2 equivalent (tCO2e) using its GWP.
Step 1: set your organisational boundary
Before counting anything, you decide which parts of the group are “yours”. The Corporate Standard offers two approaches, and you must apply your choice consistently across the whole inventory:
- Equity share: you account for emissions in proportion to your economic interest in each operation. A 30% stake means 30% of its emissions.
- Control: you account for 100% of emissions from operations you control and 0% from those you do not, using one of two definitions:
- Financial control: you can direct the operation’s financial and operating policies with a view to gaining economic benefits. This usually mirrors whether an entity is consolidated in your financial statements.
- Operational control: you (or a subsidiary) have full authority to introduce and implement operating policies at the operation.
The choice matters for joint ventures, franchises and leased assets, and it ripples through every number you report.
Scope 1: direct emissions
Scope 1 covers emissions from sources you own or control. The Corporate Standard groups them into four types:
- Stationary combustion: boilers, furnaces, turbines and generators burning gas, oil or coal.
- Mobile combustion: company-owned or controlled cars, vans, trucks, ships and aircraft.
- Process emissions: emissions from physical or chemical processes, such as CO2 from clinker production in cement.
- Fugitive emissions: intentional or unintentional releases, such as refrigerant leaks from air conditioning and methane leaks from pipelines.
Scope 2: purchased energy and dual reporting
Scope 2 covers emissions from generating the electricity, steam, heat and cooling you buy and consume. Since the 2015 Scope 2 Guidance, companies operating in markets with contractual instruments (renewable certificates, supplier-specific tariffs, power purchase agreements) shall report Scope 2 in two ways, a practice called dual reporting:
- Location-based method: uses average grid emission factors for the places where you consume electricity. It shows the physical intensity of the grids you rely on.
- Market-based method: uses the emission factors attached to the contracts you have chosen, such as energy attribute certificates (Guarantees of Origin in Europe, RECs in North America), green tariffs or a residual mix if you have no contract.
The Scope 2 Quality Criteria
To use a contractual instrument in the market-based total, it must meet the Scope 2 Quality Criteria. In summary, instruments must:
- Convey the direct GHG emission rate attribute of the electricity produced.
- Be the only instrument carrying that claim.
- Be tracked and redeemed, retired or cancelled by or for the reporting company.
- Be issued and redeemed as close as possible to the period of consumption.
- Be sourced from the same market as the consuming operations.
Further criteria cover utility-specific emission factors (calculated on delivered electricity), direct contracts and on-site generation (claims transferred only to the reporting company), and the availability of an adjusted residual mix, or disclosure of its absence. These criteria are exactly what the current revision is tightening (see below).
Scope 3: the 15 value chain categories
Scope 3 covers all other indirect emissions in your value chain. For most companies it is the largest share of the footprint. The Scope 3 Standard defines 15 categories:
| Upstream | Downstream |
|---|---|
| 1. Purchased goods and services | 9. Downstream transportation and distribution |
| 2. Capital goods | 10. Processing of sold products |
| 3. Fuel- and energy-related activities (not included in scope 1 or scope 2) | 11. Use of sold products |
| 4. Upstream transportation and distribution | 12. End-of-life treatment of sold products |
| 5. Waste generated in operations | 13. Downstream leased assets |
| 6. Business travel | 14. Franchises |
| 7. Employee commuting | 15. Investments |
| 8. Upstream leased assets |
Category 15 (investments) is critical for banks, insurers and asset managers, where it covers financed emissions. For a practical walk-through of data sources and supplier engagement, see our Scope 3 emissions guide.
Base year and recalculation
To track progress you need a fixed reference point. The Corporate Standard requires you to:
- Choose and report a base year for which verifiable data exist, and explain why you chose it. A single year is most common; a multi-year average is permitted.
- Adopt a recalculation policy, including any “significance threshold” you use, and disclose it.
- Recalculate the base year when significant changes would otherwise distort comparisons: structural changes (mergers, acquisitions, divestments, outsourcing or insourcing), changes in calculation methods or emission factors, or the discovery of significant errors. Recalculate for both increases and decreases.
The Corporate Standard does not define “significant”. It notes that some programmes use a numerical threshold, citing 10% of base year emissions as one example. Organic growth or decline is not a reason to recalculate. Target-setting bodies such as the SBTi add their own recalculation triggers.
The revision: what is changing and when
The GHG Protocol is running a full update of its corporate standards, overseen by an Independent Standards Board (ISB) with Technical Working Groups for each topic. As of November 2026, no revised standard has been finalised. The 2004 Corporate Standard, the 2015 Scope 2 Guidance and the 2011 Scope 3 Standard remain the versions in force.
Partnership with ISO
On 9 September 2025 the GHG Protocol and ISO announced a strategic partnership to harmonise the ISO 1406X family (including ISO 14064-1) with the Corporate Standard, Scope 2 Guidance and Scope 3 Standard, and to co-develop a product carbon footprint standard.
Timeline as of November 2026
| Date | Milestone |
|---|---|
| 20 Oct 2025 to 31 Jan 2026 | Scope 2 public consultation (extended from 19 Dec 2025) |
| 29 Jul 2026 | New timeline approved; summary of Scope 2 consultation feedback published |
| Late Oct 2026 | Scope 2 Technical Working Group workshop on deliverability, incrementality and feasibility |
| Q2 2027 | Consolidated public consultation covering Scopes 1, 2 and 3 and actions and market instruments |
| Q4 2028 | Planned publication of the consolidated GHG Protocol and ISO corporate standard |
The 29 July 2026 update confirmed that the Corporate Standard, Scope 2 Guidance and Scope 3 Standard will be consolidated into one joint standard, expected in a two-part structure with supporting guidance. No effective date or transition period has yet been announced.
Scope 2: hourly matching and deliverability
The October 2025 consultation draft kept dual location-based and market-based reporting but proposed that market-based claims match the hour (hourly matching) and the deliverable grid region (deliverability) of the electricity consumed. It also proposed exemption thresholds for smaller or less data-ready organisations and a legacy clause for existing contracts.
Feedback was split. According to the GHG Protocol’s 16 October 2026 status update, in July 2026 the Independent Standards Board indicated majority support for developing two market-based methods:
- Method 1: includes hourly matching, deliverability and incrementality requirements.
- Method 2: keeps the existing 2015 requirements.
The proposed direction is that companies may use Method 2 until a date still to be decided, after which Method 1 would apply where quality data are available. This is a direction of travel, not a final decision. Expect the detail in the Q2 2027 consultation.
Scope 3 and actions and market instruments
Scope 3 work (data quality, boundary setting, Category 15 investments and category-specific boundaries) is still at draft stage and will feed into the same Q2 2027 consultation. A separate workstream on actions and market instruments is developing how companies report interventions such as carbon credits and certificates alongside, rather than inside, the physical inventory.
How regulation builds on the GHG Protocol
The GHG Protocol is voluntary, but laws have turned it into a de facto requirement:
- EU CSRD (ESRS E1): the 2023 ESRS require companies to consider the principles, requirements and guidance of the GHG Protocol Corporate Standard (version 2004), screen Scope 3 using its 15 categories, and report Scope 2 on both location-based and market-based bases. A revised, simplified ESRS delegated act was adopted by the Commission on 3 July 2026 and is expected to apply from financial year 2027; check the final text for E1 detail. See our CSRD compliance guide.
- ISSB IFRS S2: requires greenhouse gas emissions to be measured in accordance with the GHG Protocol Corporate Standard (2004), with Scope 3 categorised by the 15 categories. Amendments issued in December 2025, effective for periods from 1 January 2027, add relief: jurisdictions may require a different method, and Category 15 can be limited to financed emissions. See our IFRS S1 and S2 guide.
- California SB 253: applies to businesses formed under US federal or state law with total annual revenues over $1 billion that do business in California, and requires GHG Protocol-based reporting of Scopes 1 and 2, then Scope 3. CARB’s September 2026 guidance set the first Scope 1 and 2 deadline at 10 November 2026, with first-year enforcement discretion. Rules for 2027 onwards are still being written. See our SB 253 and SB 261 guide.
One wrinkle: the ESRS default boundary is financial control, while many companies have historically used operational control for GHG Protocol and ISSB reporting. Groups reporting under both regimes should check how they reconcile the two.
First steps for a new inventory
- Pick your boundary approach and document it, aligned with your financial consolidation where possible.
- List your sites, fleets and processes and collect Scope 1 fuel, refrigerant and process data.
- Collect electricity and heat data by site and calculate Scope 2 both location-based and market-based. Keep certificate and contract evidence, and start holding hourly or half-hourly meter data now, because Method 1 may need it.
- Screen all 15 Scope 3 categories with spend-based estimates, then improve the biggest ones with supplier or activity data. Our carbon calculator can give a first estimate.
- Choose a base year and write a recalculation policy with a stated significance threshold.
- Plan for assurance: CSRD, SB 253 and many ISSB jurisdictions require or are moving towards limited assurance, so keep an audit trail.
- Track the revision: respond to the Q2 2027 consultation if you buy renewable certificates at scale, and avoid long contracts that would fail a deliverability test without a legacy clause.
Key takeaways
- The GHG Protocol Corporate Standard (2004), Scope 2 Guidance (2015) and Scope 3 Standard (2011) remain in force as of November 2026.
- Boundaries can follow equity share, financial control or operational control; apply one consistently.
- Inventories cover seven gases, including NF3 since 2013.
- Scope 2 must be dual reported (location-based and market-based) where contractual instruments exist, and instruments must meet the Scope 2 Quality Criteria.
- Scope 3 has 15 categories, eight upstream and seven downstream.
- A joint GHG Protocol and ISO corporate standard is planned for publication in Q4 2028, after a consolidated consultation in Q2 2027; Scope 2 is heading towards a two-method market-based framework.
- CSRD, IFRS S2 and California SB 253 all rely on GHG Protocol methods, so a clean inventory serves every regime.